LCR's 14000 series are hermetically sealed bulkhead mounting tubular filters constructed utilizing high quality feed-thru capacitors to achieve excellent high frequency performance.
Specifications
Manufactured to meet or exceed the requirements of MIL-F-15733
Insertion loss is measured in accordance with MIL-STD-220 under load conditions.
Operating temperature is -55°C to +155°C continuous duty.
Maximum expected temperature rise is 20°C when operated at rated voltage and current.
LCR Filters are designed to operate continuously at their rated voltage and current from DC through 400Hz.
LCR Filters will operate at 140% of their rated current for 15 minutes without degradation of performance.
LCR Filters are 100% tested at twice their rated DC voltage for 2 minutes (dielectric strength test).
Insulation resistance of LCR Filters are in excess of 1,000 M ohm µF.
Filter specifications table and insertion loss data (PDF)